Product introduction
MODEL                                     IX-P60-12V IX-P60-24V
OUTPUT DC Voltage 12V 24V
Rated Current 5A 2.5A
Current Range 0~5A 0~2.5A
Rated Power 60W 60W
Ripple & Noise(max.) 150mW 150mW
Voltage Tolerance ±2% ±2%
Setup,Rise Time 80ms/220v AC
Hold up Time 60ms/220v AC
INPUT Voltage Range 110-250v AC
Frequency Range 50~60Hz
Power Factor PF>0.6/220v AC
Efficiency 83% 84%
AC Current 0.56A/220v AC
PROTECTION Short Circuit Protection type : recovers automatically after fault condition is removed
Overload overload protected @115-140% above peak rating
Over Temperaturet Protection type: Shut down O/P voltage,re-power on to recover
ENVIRONMENT Working Temperature -30~+50℃(Refer to output load derating curve)
Working Humidity 20-90% RH non-condensing (waterproof)
Storage Temp., Humidity -40~+80℃, 10~99% RH
SAFETY&EMC Safety Standards CE Mark (LVD)
With stand Voltage I/P-O/P:1.5KV/AC I/P-GND:1.5KV/AC
EMC Test Standards EN55015:2006 ;EN61547 :1995+A1:2000;
EN61000-3-2:206;EN61000-3-3:1992+A2:2005;
EN61347-1:2001;EN61347-2-13:2006
Structure